PDF: OneNAND Very Large Page 34nm MCP.pdff Micron Technology, Inc., reserves the right to change products or specifications without notice.
OneNAND Very Large Page 34nm MCP - Rev. B 8/11 EN
6 ©2010 Micron Technology, Inc. All rights reserved.
OneNAND Compatible VLP 34nm + LPSDRAM, MCP
Signal descriptions
Micron Confidential and Proprietary Preliminary
Signal descriptions
Table 2Signal names provides a brief overview of signals connected to the devices.
Table 2: Signal names
Signal
symbol
Alternate
signal
symbol Function Type Description
NC
-
Not connected
internally
Not connected internally
DU
-
Do not use
Do not use
OneNAND Flash memory (Mux)
O-ADQ[15:0]
-
Data input/
outputs or
address inputs,
command
inputs
Inputs/
Outputs
Multiplexed address/data (ADQ[15:0]) can be used for
multiple purposes:
Address input during read operations to access the
RAM buffer and the register
Data input during program operations
Commands inputs
Data output during read operations from the memory
array or from registers
ADQ[15:0] are left floating when the device is dese-
lected or the outputs disabled.
O-CE#
E
F
Chip Enable
Input Activates the Flash memory control logic, input
buffers, decoders and sense amplifiers.
When O-CE# is at VIL, the device is in active mode.
When O-CE# is at VIH, the memory is deselected, the
outputs are high impedance and the power consump-
tion is reduced to standby level.
O-OE#
G
F
Output Enable
Input
Controls data outputs during the bus read operation of
the memory.
O-WE#
W
F
Write Enable
Input
Controls the bus write operation of the memory's
command interface.
O-RP#
RST
, RP
F
Reset
Input Provides a hardware reset of the memory.
When O-RP# is at VIL, the device is in reset mode. All
blocks are in the locked state and the configuration
register is reset.
When O-RP# is at VIH, the device is in normal opera-
tion. Upon exiting reset mode, the device enters asyn-
chronous read mode, but a negative transition of O-
CE# or O-ADV# is required to ensure valid data
outputs.
O-CLK
CK, K
F
Clock
Input Synchronizes the memory to the system bus
frequency, during synchronous burst mode.
The addresses are latched on the first O-CLK rising
edge when O-ADV# is at VIL.