ICT 2.0.1 AV Standards Addenda and Updates
Deakin eSolutions
Page 15 of 23
Version: 1.1.2 Oct 2013
Equipment
Make / Model
Twisted Pair Transceivers
Twisted Pair AV Transmitters
AMX DXLink family
Twisted Pair AV Receivers
AMX DXLink family
Twisted Pair mic/audio
Transmitters
RDL contact DeS AVN for details
Twisted Pair mic/audio
Receivers
RDL contact DeS AVN for details
Ethernet control transceivers
AMX – ICSLan EXB family: EXB-COM2 (2 serial), EXB-IRS4 (4 IR), EXB-I/O8
(8 I/O), EXB-MP1 (1 serial, 1 IR, 2 I/O), EXB-REL8 (8 relay)
Cable
Twisted Pair Cable for video
including HDbaseT
Cat-6A only
Twisted Pair Cable for audio,
control, Ethernet
as per Deakin Network Standards refer ICT Volume 6
HDMI
HDMI “High Speed” (Category 2) standard
(i.e. certified to 340 MHz and 10.2 Gbit/s)
Room Control/Automation
Large Room (AV06-AV08)
AMX NI-3100/4100, DGX/DVX (models as above)
Touchscreen (AV06-AV08)
WUXGA ELO touchscreen with AMX TPI-PRO-DVI-4
AV05 teaching space
AMX Novara CP-3008; or DVX with AXLINK keypad
Medium Room (AV04)
Cisco Touch-8, in some cases in conjunction with autonomous DVX controller –
contact DeS AVN for details
Medium Room (AV03)
generally not required; otherwise as per AV05 above
Small Room (AV01-AV02)
n/a
Wireless Touchscreen
do not use – use components listed above instead (iPad under evaluation)
PIR Motion Sensor
contact DeS AVN for details
Lighting Control
All Controlled Spaces
DALI/Dynalight
Power
UPS
1
APC SUA3000XLI* APC Smart-UPS RT 3000VA 230V complete with AP9631
SMARTSLOT SNMP + ENVIRO MONITORING
Power Line Filter
1
,
for single items of equipment
powered directly from a single
GPO only
2
Belkin F9H100vauCW SurgeCube
Power Distribution Unit, all
non-rack-mount applications
3
7-way: Thor Smart Filter D1/45B
2-way: Thor Smart Filter C2 – under evaluation – contact DeS AVN for details
(with inbuilt Power Line Filter)
Power Distribution Unit, for all
rack-mount applications
1
:
1
in existing buildings where wired-in dedicated AV UPS circuit not available;
as per Deakin Standards (sect. 9.1) all new building installations require dedicated AV circuit/s with wired-in UPS.
2
as per Deakin Standards (sect. 9.1, 7.26): Double-adaptors and power-boards are NEVER to be used.
3
as per Deakin Standards (sect. 9.1, 7.26): Double-adaptors and generic power-boards are NEVER to be used.