AMX BCS Technické informace Strana 26

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 47
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 25
Shuttle manual input features
The default setting of the manual input of the Shuttle:
- pulse connection between pin 3 and 1 system OPENS,
- pulse connection between pin 3 and 8 system CLOSES.
Manual input of the Shuttle can be programmed different with a Shuttle IR programming remote 5201002250
and a Shuttle IR receiver 5201001260:
1) SPST : pulse connection between 3 and 8: OPEN STOP CLOSE STOP
2) STOP on SPDT manual input release (in case when pulse contacts are not available):
- connection between pin 3 and 1 → system OPENS until connection is released,
- connection between pin 3 and 8 → system CLOSE until connection is released.
3) Swap OPEN and CLOSE on SPDT, invert SPST:
Reset manual input features
Note: manual input features are also reset to default setting when the Shuttle is reset to default by means of configuration button on
Shuttle motor.
04/2011 WDOC SHMANINPUT www.forestgroup.nl
26
Zobrazit stránku 25
1 2 ... 21 22 23 24 25 26 27 28 29 30 31 ... 46 47

Komentáře k této Příručce

Žádné komentáře