AMX NI-2000 Uživatelská příručka Strana 16

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 38
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 15
Introduction
12
NI-2000, NI-3000, NI-4000 Hardware Reference Guide
NI-4000 Specifications (Cont.)
Rear Panel Connectors:
RS-232/422/485 (Ports 1 -7) Seven RS-232/422/485 control ports using DB9 (male) connectors with
XON/XOFF (transmit on/transmit off), CTS/RTS (clear to send/ready to
send), and 300-115,200 baud.
Channel range = 1-255
Channels 1-254 provide feedback
Channel 255 (CTS Push channel): Reflects the state of the CTS Input if a
'CTSPSH' command was sent to the port
Output data format for each port is selected via software
Seven DB9 connectors provide RS-232/422/485 termination
ICSNet Two RJ-45 connectors for ICSNet interface
ICSHub Out RJ-45 connector provides data to another Hub connected to the Controller
Relay (Port 8) Eight-channel single-pole single throw relay ports
Each relay is independently controlled.
Supports up to 8 independent external relay devices
Channel range = 1-8
Each relay can switch up to 24 VDC or 28 VAC @ 1 A
Two 8-pin 3.5 mm mini-Phoenix (female) connectors provide relay
termination
Digital I/O (Port 17) Eight-channel binary I/O port for contact closure
Each input is capable of voltage sensing. Input format is software
selectable.
Interactive power sensing for IR ports
Channel range = 1-8
All inputs are assigned to respective IR/Serial ports for "automatic" power
control through the use of software commands. Power control is provided
via commands such as: ’PON’, ’POF’, ’POD’, ’DELAY’, I/O Link etc.).
Contact closure between GND and an I/O port is detected as a PUSH
When used as voltage input - I/O port detects a low signal (0- 1.5 VDC) as a
PUSH and a high signal (3.5 - 5 VDC) as a RELEASE
When used as an output - each I/O port acts as a switch to GND and is
rated at 200 mA @ 12 VDC
10-pin 3.5 mm mini-Phoenix (female) connector provides I/O port
termination
Note: This IO port uses 5V logic but can handle up to 12V without harm. It
can handle up to 12V on the input. At higher voltages you run a higher risk of
surge damage.
IR/Serial (Ports 9-16) Eight IR/Serial control ports support high-frequency carriers of up to 1.142
MHz.
Each output is capable of three electrical formats: IR, Serial, and Data
Eight IR/Serial data signals can be generated simultaneously.
Channel range = 1-32,767
Channels 1-128 (output): IR commands
Channels 129-253: used as reference channels
Channel 254 (feedback): Power Fail (used with 'PON' and 'POF'
commands)
Channel 255 (feedback): Power status (when IO Link is set)
IR ports support data mode (at limited baud rates and wiring distances).
Two 8-pin 3.5 mm mini-Phoenix (female) connectors provide IR/Serial port
termination