Speaker Output: 10 Watt internal siren driver with full speech
10 Watt external siren driver with full speech
Designed for use with 8W, 10 watt minimum speakers.
Total impedance for either driver not to drop below 4W
For UL installations use a Ademco 705 speaker which must be connected to "EXT" and "CON"
terminals.
Smoke Detectors: ESL 429 Series - 2 wire Photoelectric
System Sensor 2112/24B - 4 wire Photoelectric (Not evaluated for UL installation)
System Sensor 2112/24BT - 4 wire Photoelectric (Not evaluated for UL installation)
w/heat sensor
System Sensor 2100 - 2 wire Photoelectric (Not evaluated for UL installation)
System Sensor 2100T - 2 wire Photoelectric (Not evaluated for UL installation)
w/heat sensor
Dimensions: 15.1" L x 13.05" W x 3.5" D w/ door.
System Keypads: Fully spoken enunciation of zones and system status
6 Programmable manual activations
Lights and appliance control for home automation
3-way Monitor mode - Speech, Silence, Chime
Dimensions: 7" x 4 3/4" x 1" deep
Keypad Wiring: 4-wire bus
-red and black - power
-green and white - data
2-violet - audio
No smaller than 24 gauge, up to 50', 22 gauge over 50'
Microphone wire- 22 gauge, 2 conductor shielded
Transient Protection: Multiple level surge filters are on all zone inputs, power supply, keypad connection, siren outputs,
auxiliary power supply, and the telephone interface. The circuit board is designed to provide spark
gap protection to catch high voltage impulses at the wiring terminals. Protective ground planes
surround sensitive areas preventing the spread of damaging voltage surges. Metal Oxide Varistors
(MOV's) are in all critical areas to further reduce surges. Sidactors and PTC Thermistors protect the
phone line input. Transient protection is most effective when the panel is earth grounded.
Nonvolatile Memory: Maintains programming options with no power to the control.
System clock: Time-of-day clock with a backup circuit designed to deliver continuous power for two weeks on a
full charge.
System Watchdog: All precautions have been taken to prevent spurious operation of the control caused by voltage
surges, however, temporary disruption of the microprocessor can occur, leading to improperly
processed routines. The system is equipped with a watchdog circuit that watches processor
operation and resets the microprocessor if an error should occur.
Supervision: The following trouble conditions are always monitored:
Loss of AC power
Backup battery low voltage
Communicator failure
Phone line loss
High current conditions (system shorts)
Zone expansion failure
Receiver or bridge board failure (panel supervises bridge, bridge supervises receiver(s))
Transmitter supervision signals - trouble indication within 6 hours (if programmed)