Amx Metreau Entry Communicator with Display MET-ECOM-D Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Bezpečnost Amx Metreau Entry Communicator with Display MET-ECOM-D. AMX Metreau Entry Communicator with Display MET-ECOM-D User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 84
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
Operation/Reference Guide
Voice and Video Communication Systems
Metreau
Entry Communicators
MET-ECOM Metreau Entry Communicator
MET-ECOM-D Metreau Entry Communicator with Display
Last Revised: 8/04/2008
Zobrazit stránku 0
1 2 3 4 5 6 ... 83 84

Shrnutí obsahu

Strany 1 - Entry Communicators

Operation/Reference GuideVoice and Video Communication SystemsMetreau™ Entry CommunicatorsMET-ECOM Metreau Entry CommunicatorMET-ECOM-D Metreau Entry

Strany 2

Metreau Entry Communicators4 Metreau Entry CommunicatorsMET-ECOM Specifications (Cont.)Microphone: • -40 dB sensitivity, built-in echo cancellation (t

Strany 3 - Table of Contents

Metreau Entry Communicators5 Metreau Entry Communicators Product Specifications - MET-ECOM-D MET-ECOM-D SpecificationsPower: • PoE powered – no local

Strany 4

Metreau Entry Communicators6 Metreau Entry CommunicatorsMET-ECOM-D Specifications (Cont.)Operating Environment: 32° to 104° F (0° to 40° C)Mounting: T

Strany 5 - Metreau Entry Communicators

Positioning the Camera7 Metreau Entry Communicators Positioning the CameraOverviewThe camera on the Metreau Entry Communicators provides a symmetrical

Strany 6

Positioning the Camera8 Metreau Entry CommunicatorsFIG. 5 MET-COM-D Camera: Left and Right Viewing RangeLRLRLRTop view when camera is centered at 0°T

Strany 7

Wiring and Connections9Metreau Entry Communicators Wiring and ConnectionsOverviewThe installation section addresses the mounting and wiring of the Met

Strany 8 - Front Components

Wiring and Connections10 Metreau Entry CommunicatorsEthernet 10/100 Base-T RJ-45 Wiring ConfigurationThe table below describes the pinouts, signals, a

Strany 9 - Rear Components

Wiring and Connections11Metreau Entry Communicators Input/Output (I/O) Port: Connections and WiringThe I/O port responds to either switch closures, vo

Strany 10

Wiring and Connections12 Metreau Entry CommunicatorsFerrite Installation (Required)Metreau Entry Communicators comes with a Cat5 Suppression Ferrite t

Strany 11 - MET-ECOM-D Specifications

Wiring and Connections13Metreau Entry Communicators System DiagramFIG. 10 provides a basic NetLinx system diagram using Metreau Entry Communicators: S

Strany 12

AMX Limited Warranty and DisclaimerThis Limited Warranty and Disclaimer extends only to products purchased directly from AMX or an AMX Authorized Part

Strany 13 - Positioning the Camera

Wiring and Connections14 Metreau Entry Communicators

Strany 14

Mounting and Installation15 Metreau Entry Communicators Mounting and InstallationMET-ECOM / MET-ECOM-D Installation OverviewThis section addresses the

Strany 15 - Wiring and Connections

Mounting and Installation16 Metreau Entry CommunicatorsMounting SpecificationsThe following illustrations (FIG. 13, FIG. 14 and FIG. 15) provide mount

Strany 16 - PoE (Power Over Ethernet)

Mounting and Installation17 Metreau Entry Communicators Side Views Top View FIG. 14 Mounting Specifications (side views)FIG. 15 Mounting Specificati

Strany 17 - Connecting The Device via I/O

Mounting and Installation18 Metreau Entry CommunicatorsTypical Installation (Without Expansion Clips)FIG. 16 provides specifications for mounting the

Strany 18 - (FIG. 9)

Mounting and Installation19 Metreau Entry Communicators 5. Install the (provided) Ferrite clip onto the Ethernet cable (see FIG. 8 on page 12).6. Conn

Strany 19 - System Diagram - Intercom

Mounting and Installation20 Metreau Entry CommunicatorsInstalling the Wall Box Without the Use of TabsA brick and mortar installation environment is a

Strany 20 - Metreau Entry Communicators

Mounting and Installation21 Metreau Entry Communicators Wall Surface Installation (Using Expansion Clips)Expansion clips are mounted through the 2 hol

Strany 21 - Mounting and Installation

Mounting and Installation22 Metreau Entry Communicators4. Install the 2 drywall screws and expansion clips into the 2 locations along both sides of th

Strany 22 - Mounting Specifications

Mounting and Installation23 Metreau Entry Communicators 8. Install the (provided) Ferrite clip onto the Ethernet cable (see FIG. 8 on page 12).9. Conn

Strany 23 - Top View

Table of ContentsiMetreau Entry Communicators Table of ContentsMetreau Entry Communicators ...

Strany 24

Mounting and Installation24 Metreau Entry Communicators6. Place the lug of the ground wire on the device and the Earth ground wire around the provided

Strany 25

Mounting and Installation25 Metreau Entry Communicators Using the Optional Surface Mount BoxThe CB-MET-ECOMS (-S/-B) Surface Mount Box Kit for Metreau

Strany 26

Mounting and Installation26 Metreau Entry CommunicatorsSurface Mount Box SpecificationsFIG. 22 provides mounting specifications for the CB-MET-ECOMS:

Strany 27

Mounting and Installation27 Metreau Entry Communicators Ferrite Installation (Required)The CB-MET-ECOMS comes with a Cat5 Suppression Ferrite that mus

Strany 28

Mounting and Installation28 Metreau Entry Communicators1. Run all cables through the Conduit Routing Hole on the rear panel of the Surface Mounting Bo

Strany 29

Using the Configuration Manager29 Metreau Entry Communicators Using the Configuration ManagerOverviewMetreau Entry Communicators have a built-in web c

Strany 30

Using the Configuration Manager30 Metreau Entry CommunicatorsCommand ButtonsThe Configuration Manager is divided into four primary sections, indicated

Strany 31 - Included in the Kit

Using the Configuration Manager31 Metreau Entry Communicators Summary of <Device> Settings PageThe Summary of Device Settings page (FIG. 28) is

Strany 32

Using the Configuration Manager32 Metreau Entry CommunicatorsChecking the Firmware VersionThe firmware version is listed on the Summary of Device Sett

Strany 33 - (complete)

Using the Configuration Manager33 Metreau Entry Communicators Configuration PageClick the Configuration command button to access the Configuration pag

Strany 34

ii Metreau Entry CommunicatorsTable of ContentsInstalling the Metreau Entry Communicator...

Strany 35 - Overview

Using the Configuration Manager34 Metreau Entry CommunicatorsSetting the IP Address1.In the Configuration page, select the IP Settings tab.2. Click th

Strany 36

Using the Configuration Manager35 Metreau Entry Communicators Configuration Page - NetLinx Settings TabSelect the NetLinx Settings tab of the Configur

Strany 37

Using the Configuration Manager36 Metreau Entry Communicators5. If you have enabled password security on your master, you need to set the username and

Strany 38

Using the Configuration Manager37 Metreau Entry Communicators Device Utilities PageClick the Utilities command button to access the Device Utilities p

Strany 39 - Configuration Page

Using the Configuration Manager38 Metreau Entry CommunicatorsImage File RequirementsIn order for images to be displayed on the MET-ECOM-D, the followi

Strany 40

Using the Configuration Manager39 Metreau Entry Communicators 2. Save the file as a ".BMP" image (FIG. 34). 3. Reduce the BMP image to 128 x

Strany 41

Using the Configuration Manager40 Metreau Entry Communicators Check your graphics editing program for options relative to the reduction method applie

Strany 42

Using the Configuration Manager41 Metreau Entry Communicators Creating a New Dynamic Image1.In TPDesign4, select Panel > Resource Manager to access

Strany 43 - Device Utilities Page

Using the Configuration Manager42 Metreau Entry Communicators4. Click OK.Uploading a Display Image To The Device1.Under File Upload, click the Browse

Strany 44 - Creating Display Images

Using the Configuration Manager43 Metreau Entry Communicators Audio/Video PageAudio/Video Page - Audio Settings TabClick on the Audio tab of the Audio

Strany 45

Table of ContentsiiiMetreau Entry Communicators LCD Commands...

Strany 46 - Creating Dynamic Images

Using the Configuration Manager44 Metreau Entry CommunicatorsAudio/Video Page - Video Settings TabClick the Video tab in the Audio/Video Page to acces

Strany 47 - Creating a New Dynamic Image

Using the Configuration Manager45 Metreau Entry Communicators Setting Device Video1.In the Audio/Video page, select the Video tab.2. Click the radio b

Strany 48

Using the Configuration Manager46 Metreau Entry CommunicatorsSetting the Display Settings On The Device1.In the menu on the top of the Configuration M

Strany 49 - Audio/Video Page

Programming47 Metreau Entry Communicators ProgrammingOverviewThere are a select number of SEND_COMMANDs recognized by the Metreau Entry Communicators.

Strany 50

Programming48 Metreau Entry CommunicatorsTouch Panel Intercom Commands (Cont.)STREAM-SET (Cont.) Example (H.263 video stream):SEND_COMMAND MET1, "

Strany 51

Programming49 Metreau Entry Communicators RTP, RTCP Video and Audio Streaming CommandsMetreau Entry Communicators support the following RTP, RTCP Vide

Strany 52

Programming50 Metreau Entry CommunicatorsRTP, RTCP Video and Audio Streaming Commands (Cont.)SET AUDIOSets the current configuration of the audio syst

Strany 53 - Programming

Programming51 Metreau Entry Communicators Face Plate LED CommandsMetreau Entry Communicators support the following LED face plate SEND_COMMANDs on por

Strany 54

Programming52 Metreau Entry CommunicatorsCamera CommandsThe Metreau Entry Communicators Camera (MET-ECOM-D only) supports the following camera SEND_CO

Strany 55 - SEND_COMMANDs on port 1

Programming53 Metreau Entry Communicators Camera Commands (Cont.)SET CAM-CSTSets the display contrast level for the camera.Syntax:"'SET CAM-

Strany 56

iv Metreau Entry CommunicatorsTable of Contents

Strany 57 - Face Plate LED Commands

Programming54 Metreau Entry CommunicatorsLCD CommandsThe LCD located on the face plate (MET-ECOM-D only) supports the following SEND_COMMANDs on port

Strany 58 - Camera Commands

Programming55 Metreau Entry Communicators LCD Commands (Cont.)SET DISP-BRTSets the brightness level to a percentage.The LCD display sup-ports quad (25

Strany 59 - Camera Commands (Cont.)

Programming56 Metreau Entry CommunicatorsI/O CommandsThe I/O port supports the following SEND_COMMANDs on port 2. There are two channels on port 2: Ch

Strany 60 - LCD Commands

Programming57 Metreau Entry Communicators System Commands (Cont.)SET DOOR-DESCSet the door description text.Syntax:SEND_COMMAND <DEV>,"&apo

Strany 61 - LCD Commands (Cont.)

Programming58 Metreau Entry CommunicatorsUpgrading FirmwareBefore beginning the Upgrade process Setup and configure your NetLinx Master. Refer to you

Strany 62 - System Commands

Programming59 Metreau Entry Communicators 10. Click OK three times to close the open dialogs and save your settings.11. Click Yes to interrupt the cu

Strany 63 - System Commands (Cont.)

Programming60 Metreau Entry Communicators6. Select the device’s firmware file from the Files section (FIG. 43).7. Enter the Device value associated wi

Strany 64 - Upgrading Firmware

Using the NetLinx Module61 Metreau Entry Communicators Using the NetLinx ModuleOverviewMetreau Entry Communicators can be controlled via the Touch Pag

Strany 65

Using the NetLinx Module62 Metreau Entry CommunicatorsSetting the Intercom Session TimeoutWhen only 30 seconds are left in your call, the panel provid

Strany 66 - Send to NetLinx Device dialog

Using the NetLinx Module63 Metreau Entry Communicators Door SetupThe Door Setup page (FIG. 46) is accessed through the Intercom Setup page. The option

Strany 67 - Using the NetLinx Module

Metreau Entry Communicators1 Metreau Entry Communicators Metreau Entry CommunicatorsOverviewThe Metreau Entry Communicators (FIG. 1) can be placed at

Strany 68 - FIG. 45 Extend Call Popup

Using the NetLinx Module64 Metreau Entry CommunicatorsDoor Chime SetupThe Door Chime Setup page (FIG. 47) is accessed through the Door Setup page. The

Strany 69 - Disabling All Doorbells

Using the NetLinx Module65 Metreau Entry Communicators Advanced SetupThe Intercom Advanced Setup page (FIG. 48) is accessed through the Intercom Setup

Strany 70 - Door Chime Setup

Using the NetLinx Module66 Metreau Entry CommunicatorsAllowing a Panel To Monitor1.Select the Setup button on your intercom page.2. On the intercom se

Strany 71 - FIG. 49 Room Monitored

Using the NetLinx Module67 Metreau Entry Communicators Answering an Incoming Doorbell CallThe provided intercom pages include a doorbell answering pop

Strany 72 - Answer Call

Using the NetLinx Module68 Metreau Entry CommunicatorsThe options in this page allow you see and view the incoming doorbell call, as well as adjust th

Strany 73 - Someone At The Door Page

Using the NetLinx Module69 Metreau Entry Communicators Door Chime Setup page Door Setup page Door Chime SetupName Description ChannelPort:CodeAddres

Strany 74 - Creating Intercom Pages

Using the NetLinx Module70 Metreau Entry CommunicatorsIntercom Demo pageThe module for duplex intercom capable panels includes user pages. While you c

Strany 75 - Door Setup page

Using the NetLinx Module71 Metreau Entry Communicators Sample Intercom Page (Cont.)No. Name Description ChannelPort:CodeAddressPort:CodeLevelPort:Code

Strany 76 - Intercom Demo page

Using the NetLinx Module72 Metreau Entry CommunicatorsSetup page Sample Intercom Page (Cont.)No. Name Description ChannelPort:CodeAddressPort:CodeLeve

Strany 77 - Sample Intercom Page (Cont.)

Using the NetLinx Module73 Metreau Entry Communicators Someone At The Door page Someone At The DoorName Description ChannelPort:CodeAddressPort:CodeL

Strany 78 - Setup page

Metreau Entry Communicators2 Metreau Entry CommunicatorsFront ComponentsThe front components of the Metreau Entry Communicators are indicated in FIG.

Strany 79 - Someone At The Door page

Using the NetLinx Module74 Metreau Entry CommunicatorsCreating Popup PagesDoor Answer Call popup page Doorbell Adjustments popup page Someone At The D

Strany 80 - Creating Popup Pages

Using the NetLinx Module75 Metreau Entry Communicators Intercom Answer Call popup page Doorbell Adjustments Popup (Cont.)Name Description ChannelPort:

Strany 81 - Intercom Answer Call Popup

Using the NetLinx Module76 Metreau Entry CommunicatorsMore Time popup page More Time PopupName Description ChannelPort:CodeAddressPort:CodeConfirm Mo

Strany 82 - More Time popup page

Programming77Metreau Entry Communicators

Strany 83

8/08 ©2008 AMX. All rights reserved. AMX and the AMX logo are registered trademarks of AMX. AMX reserves the right to alter specifications without not

Strany 84

Metreau Entry Communicators3 Metreau Entry Communicators Rear ComponentsThe rear components of the Metreau Entry Communicators are indicated in FIG. 3

Komentáře k této Příručce