AMX AVS-MD4-CP10 Manuál s instrukcemi Strana 15

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 22
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 14
Installing a CP-10 Remote Control Panel
12
CP-10 Instruction Manual
Installing a CP-10 Remote Control Panel
This chapter covers rack installation for the CP-10 Remote Panel (FG1090-216), as well as instructions
for linking the panel to an enclosure. When the installation is complete, execute a test switch to make
sure the system is working properly (see page 15).
General Specifications
Rear View
Parameter Value
Cable for XNNet
Communications
Two-conductor, 20 AWG, 7/28 strand cable with a drain wire or shield, such
as Alpha 2412C (customer supplied)
Maximum length of cable: 1000 ft. (305 m) total, including linked panels
Power +7 VDC to +12 VDC @ 500 mA
Operational Temperature 32° F to 110° F (0° C to 43° C)
Humidity 0 to 90% non-condensing
Dimensions 1.0 in. (2.54 cm) depth
18.9 in. (48.0 cm) width with mounting ears
5.2 in. (13.21 cm) height, 3 RU
Weight Approximately 2 lb (0.91 kg) per panel
FIG. 4
Rear view of CP-10 Remote Panel
Power connector Comm Link connector
Zobrazit stránku 14