Operation/Reference GuideProduct CategoryViewStatCommunicating ThermostatLast Revised: 5/16/2008

Strany 2

Product Information4ViewStat Communicating ThermostatThe ViewStat supports up to four Support Modules, and can display any one of the following: The

Strany 3 - Table of Contents

Product Information5ViewStat Communicating ThermostatHVAC System Pre-Installation Check ListBefore getting started, determine what type of heating sys

Strany 4

Product Information6ViewStat Communicating Thermostat

Strany 5

ViewStat Installation and Wiring7ViewStat Communicating ThermostatViewStat Installation and WiringThis section covers the installation, wiring and che

Strany 6

ViewStat Installation and Wiring8ViewStat Communicating ThermostatRemoving the Faceplate from the BaseNo tools are required to disassemble the thermos

Strany 7

ViewStat Installation and Wiring9ViewStat Communicating ThermostatSetting the DIP SwitchSet the DIP switch located on the thermostat circuit board (FI

Strany 8 - ViewStat Specifications

ViewStat Installation and Wiring10ViewStat Communicating ThermostatAttaching the MiniVerter to the ViewStatBefore attaching the MiniVerter to the rear

Strany 9

ViewStat Installation and Wiring11ViewStat Communicating Thermostat9. Connect the Cat-5 RJ-45 connector on the MiniVerter to the Control System (Maste

Strany 10 - Maximum Cable Distances

ViewStat Installation and Wiring12ViewStat Communicating ThermostatMounting the Base to a WallThere are four screw holes located on the base of the th

Strany 11

ViewStat Installation and Wiring13ViewStat Communicating Thermostat3. Fasten the base to the wall with the supplied screws.4. Seal wire entry using ca

Strany 12 - Product Information

AMX Limited Warranty and DisclaimerAMX Corporation warrants its products to be free of defects in material and workmanship under normal use for three

Strany 13

ViewStat Installation and Wiring14ViewStat Communicating ThermostatConnecting to an Axcess Control System (via AXC-232++, AXB-EM232,or Axcent3/PRO)To

Strany 14

ViewStat Installation and Wiring15ViewStat Communicating ThermostatConnecting to an Axcess Master Controller via the RS232/422/485 (DB-9) PortThe tabl

Strany 15 - Setting the DIP Switch

ViewStat Installation and Wiring16ViewStat Communicating ThermostatConnecting to NetLinx Integrated Controllers via the RS232/422/485 (DB-9) PortThe t

Strany 16

ViewStat Installation and Wiring17ViewStat Communicating ThermostatConnecting to a NetLinx Master controller via NXC-COM cardThe Viewstat can connect

Strany 17

ViewStat Installation and Wiring18ViewStat Communicating ThermostatConnecting to a LandMark Control SystemPhastLink cables are used to connect all Pha

Strany 18 - Mounting the Base to a Wall

ViewStat Installation and Wiring19ViewStat Communicating ThermostatConnecting to a Landmark Control SystemTo connect a single ViewStat to a Landmark c

Strany 19 - 2 3 4 5 6 7 8

ViewStat Installation and Wiring20ViewStat Communicating Thermostat Wiring the Thermostat1. Strip 1/4" (0.63 cm) of insulation from each wire to

Strany 20

ViewStat Installation and Wiring21ViewStat Communicating ThermostatConnecting the ViewStat to the HVAC System1.Make sure the HVAC system power is off.

Strany 21 - RS232/422/485

ViewStat Installation and Wiring22ViewStat Communicating Thermostatb. FIG. 15 shows a typical heat/cool wiring schematic: FIG. 15 Typical heat pump

Strany 22

ViewStat Installation and Wiring23ViewStat Communicating ThermostatChecking HVAC System OperationUse the thermostat buttons to verify that the thermos

Strany 23

Table of ContentsiViewStat Communicating ThermostatTable of ContentsProduct Information ...

Strany 24

ViewStat Installation and Wiring24ViewStat Communicating Thermostat7. Use the up arrow button to raise the set point 3°F above room temperature. In 5-

Strany 25 - Connecting the

ViewStat Installation and Wiring25ViewStat Communicating Thermostat6. After the address has been selected, press the Enter button to store the address

Strany 26 - Wiring the Thermostat

ViewStat Installation and Wiring26ViewStat Communicating ThermostatWiring DiagramsSingle-stage furnace and AC configuration.FIG. 18 Single-stage furn

Strany 27 - CAUTION!

ViewStat Installation and Wiring27ViewStat Communicating ThermostatTwo-stage furnace and two-stage AC configuration.FIG. 19 Two-stage furnace and two

Strany 28

ViewStat Installation and Wiring28ViewStat Communicating ThermostatRoof top unit (two-stage heat and two-stage cool) configuration.FIG. 20 Roof top u

Strany 29

ViewStat Installation and Wiring29ViewStat Communicating ThermostatBoiler with AC (two transformers) configuration.FIG. 21 Boiler with AC (two transf

Strany 30 - Optional HVAC Set-Up Features

ViewStat Installation and Wiring30ViewStat Communicating ThermostatSingle-stage heat pump configurationFIG. 22 Single-stage heat pump configurationVi

Strany 31

ViewStat Installation and Wiring31ViewStat Communicating ThermostatTwo-stage heat pump configuration.FIG. 23 Two-stage heat pump configurationViewSta

Strany 32 - Wiring Diagrams

ViewStat Installation and Wiring32ViewStat Communicating ThermostatFirst- stage radiant floor heat, second-stage furnace one stage of cooling configur

Strany 33

Support Module Installation and Wiring33ViewStat Communicating ThermostatSupport Module Installation and WiringFollow the guidelines for placement of

Strany 34

iiViewStat Communicating ThermostatTable of ContentsAddress the Thermostats and Set Highest Address... 24

Strany 35

Support Module Installation and Wiring34ViewStat Communicating Thermostat6. Snap the circuit board back into the sub-base by sliding the top of the bo

Strany 36

Support Module Installation and Wiring35ViewStat Communicating Thermostat1. Remove the thermostat from the sub-base.2. Wire the first sensor using the

Strany 37

Support Module Installation and Wiring36ViewStat Communicating ThermostatDIP switches 1 and 2: Address (1-4)The following diagram shows how to set the

Strany 38

Support Module Installation and Wiring37ViewStat Communicating ThermostatApplicationsHeat Pump ApplicationsIf the support module is being used with a

Strany 39

Support Module Installation and Wiring38ViewStat Communicating ThermostatTroubleshooting Remote Sensors Thermostat has no display: Check 24 VAC supp

Strany 40 - Removing the circuit board

Set Up and Configuration39ViewStat Communicating ThermostatSet Up and ConfigurationThe ViewStat has many features that can be adjusted to customize op

Strany 41

Set Up and Configuration40ViewStat Communicating ThermostatNetwork Override Set-UpThis enables or disables the Network Override feature. When Network

Strany 42 - ADDRESS 4

Set Up and Configuration41ViewStat Communicating ThermostatSecurity Set-UpThis prevents unauthorized individuals from accessing Thermostat Set-Up. A c

Strany 43 - Applications

Set Up and Configuration42ViewStat Communicating ThermostatCommunications Set-UpThis is where the thermostat address is entered. Additionally, the tot

Strany 44

Set Up and Configuration43ViewStat Communicating ThermostatBalance Point Set-UpBalance points limit heat pump operation when the outdoor temperature i

Strany 45 - Set Up and Configuration

Table of ContentsiiiViewStat Communicating ThermostatOperating the Thermostat ...

Strany 46 - Thermostat Button Lockout

Set Up and Configuration44ViewStat Communicating ThermostatFIG. 38 Display set-upShow Temp SetptsNextDisplaySet Up MoreTemperatureScale °F°C FEXI

Strany 47 - Security Set-Up

Using the NetLinx Module to Program the ViewStat45ViewStat Communicating ThermostatUsing the NetLinx Module to Program the ViewStatAMX_ViewStat NetLin

Strany 48 - Backlighting Set-Up

Using the NetLinx Module to Program the ViewStat46ViewStat Communicating ThermostatIt is important that the serial number array be the same length as

Strany 49 - Display Set-Up

Using the NetLinx Module to Program the ViewStat47ViewStat Communicating Thermostatcool setpoint would be set to 72. While the temperature is within t

Strany 50 - FIG. 38 Display set-up

Using the NetLinx Module to Program the ViewStat48ViewStat Communicating ThermostatCommand Interface - SEND_COMMANDs (Cont.)Command Description'T

Strany 51

Using the NetLinx Module to Program the ViewStat49ViewStat Communicating ThermostatCommand Interface - SEND_COMMANDs (Cont.)Command Description'T

Strany 52 - The ViewStat Model

Using the NetLinx Module to Program the ViewStat50ViewStat Communicating ThermostatCommand Interface - SEND_COMMANDs (Cont.)Command Description'T

Strany 53

Using the NetLinx Module to Program the ViewStat51ViewStat Communicating ThermostatCommand Interface - SEND_COMMANDs (Cont.)Command Description'T

Strany 54 - 'T-1 HEAT-68'

Using the NetLinx Module to Program the ViewStat52ViewStat Communicating ThermostatString FeedbackThe NetLinx module will provide feedback to the glue

Strany 55

Using the NetLinx Module to Program the ViewStat53ViewStat Communicating ThermostatString Feedback (Cont.)String Description'T-<stat> FAN-&

Strany 56

ivViewStat Communicating ThermostatTable of Contents

Strany 57

Using the NetLinx Module to Program the ViewStat54ViewStat Communicating ThermostatString Feedback (Cont.)String Description'T-<tstat> HUMI

Strany 58 - String Feedback

Using the NetLinx Module to Program the ViewStat55ViewStat Communicating ThermostatString Feedback (Cont.)String Description'T-<tstat> TEMP

Strany 59 - String Feedback (Cont.)

Using the NetLinx Module to Program the ViewStat56ViewStat Communicating Thermostat

Strany 60

Operating the Thermostat57ViewStat Communicating ThermostatOperating the ThermostatThis section describes the front panel components, and gives instru

Strany 61

Operating the Thermostat58ViewStat Communicating ThermostatFan buttonThe fan can be operated continuously (FAN ON) or only when there is a need to hea

Strany 62

Operating the Thermostat59ViewStat Communicating ThermostatOperating The ThermostatNotes on temperature adjustments: The COOL setting must always be

Strany 63 - Operating the Thermostat

Operating the Thermostat60ViewStat Communicating Thermostat – Setting temperaturesPress the Up or Down adjust button. The setting to be changed will b

Strany 64 - Main display

Operating the Thermostat61ViewStat Communicating Thermostat

Strany 65 - HEAT COO L E M. HEAT

5/08 ©2008 AMX. All rights reserved. AMX and the AMX logo are registered trademarks of AMX. AMX reserves the right to alter specifications without no

Strany 66 - Cleaning the Thermostat

Product Information1ViewStat Communicating ThermostatProduct InformationIntroductionThe ViewStat Communicating Thermostat (FIG. 1) operates similarly

Strany 67

Product Information2ViewStat Communicating ThermostatSystem ComponentsThe components in a complete ViewStat system (including optional accessories) ar

Strany 68

Product Information3ViewStat Communicating ThermostatSupport Module Specifications There are two types of support modules available for the ViewStat: